Ahirwal, Bhagirath (2015) Design, Testing Analysis of High Tension Increased Safety Motor for Hazardous areas. TELKOMNIKA Indonesian Journal of Electrical Engineering, 15 (2). pp. 237-248.
| ![[img]](http://cimfr.csircentral.net/style/images/fileicons/application_pdf.png) | PDF Restricted to Registered users only Download (357Kb) | 
Abstract
The increased safety (Ex e) motors are designed for safe operation in the zone 1 and 2 hazardous areas. The present paper describes the significant design parameters and successful testing of Ex e high tension (HT) induction motor rated 970KW/6.6KV/18 pole/ 3Phase/ 50Hz as per IS/IEC 60079-7 standard. The comparison of some useful design parameters is also given between safe area motor and hazardous area motor in this paper. The Ex e high tension induction motor mentioned in this paper have been manufactured by Bharat Heavy Electricals Ltd. (BHEL), Bhopal, India during the project and main author was the project leader.
| Item Type: | Article | 
|---|---|
| Uncontrolled Keywords: | increased safety motor, risk factor, testing, IA/IN, tE. | 
| Subjects: | Flame Proof Laboratory | 
| Divisions: | UNSPECIFIED | 
| Depositing User: | Mr. B. R. Panduranga | 
| Date Deposited: | 24 Dec 2019 06:03 | 
| Last Modified: | 24 Dec 2019 06:03 | 
| URI: | http://cimfr.csircentral.net/id/eprint/2093 | 