Roy, S.K. and Singh, R. R. and Kumar, Ritesh (2006) Measurement of toxic gases in post detonation fumes generated by permitted explosives. Indian Mining & Engineering Journal , 45 (10). pp. 27-31. ISSN 0019-5944

Full text not available from this repository. (Request a copy)

Abstract

Commercial explosives generate some amount of toxic gases, mostly carbon monoxide (CO) and oxides of nitrogen (NOx), during their detonation in practical usage conditions. Toxic gases generated by permitted explosives used in underground mines may get accumulated in physiologically harmful concentration. Permitted explosives, being used in underground coal mines, are therefore required to meet the stipulated criteria for their toxic fumes along with other safety and sensitivity parameters. The paper presents the laboratory method for assessment of CO & NOx generated by permitted explosives in standard laboratory condition.

Item Type: Article
Subjects: Explosive and Explosion
Divisions: UNSPECIFIED
Depositing User: Dr. Satyendra Kumar Singh
Date Deposited: 21 Dec 2011 10:03
Last Modified: 21 Dec 2011 10:03
URI: http://cimfr.csircentral.net/id/eprint/439